Peer-Reviewed Journal Details
Mandatory Fields
Mirza, Z,Liu, JT,Glocheux, Y,Albadarin, AB,Walker, GM,Mangwandi, C
2015
December
Particuology
Effect of impeller design on homogeneity, size and strength of pharmaceutical granules produced by high-shear wet granulation
Published
()
Optional Fields
Granule strength Impeller design Homogeneity High-shear granulation Lactose monohydrate MECHANICAL-PROPERTIES BINDER DISTRIBUTION BATCH VARIABLES SPEED MIXER COMPRESSION FERTILIZER POROSITY BORAX
23
31
39
Small mixer impeller design is not tailored for granulation because impellers are intended for a wide range of processes. The aim of this research was to evaluate the performances of several impellers to provide guidance on the selection and design for the purposes of granulation. Lactose granules were produced using wet granulation with water as a binder. A Kenwood KM070 mixer was used as a standard apparatus and five impeller designs with different shapes and surface areas were used. The efficacy of granulate formation was measured by adding an optically sensitive tracer to determine variations in active ingredient content across random samples of granules from the same size classes. It was found that impeller design influenced the homogeneity of the granules and therefore can affect final product performance. The variation in active ingredient content across granules of differing size was also investigated. The results show that small granules were more potent than larger granules. (C) 2015 Chinese Society of Particuology and Institute of Process Engineering, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
10.1016/j.partic.2014.12.009
Grant Details