Book Chapter Details
Mandatory Fields
Healy, R,Norris, M,Kenny, IC,Harrison, AJ,Jansen, AJ
2016 June
ENGINEERING OF SPORT 11
A novel protocol to measure short sprint performance
Springer
London, UK
Published
1
Optional Fields
Optojump (TM) timing gates high speed camera validity STATISTICAL-METHODS RELIABILITY
This study assessed the validity of a novel protocol in the measurement of 5 and 10 m sprint time from standing and block starts. Sprint time was assessed using high speed video timing and a novel method which incorporated dual beam photocells synchronized with an optical measuring system. Team sport athletes and sprinters completed 10 m sprints from standing and block starts with both methods measuring sprint time concurrently. No significant differences were found between methods (p > 0.05) with a negligible mean bias (< 0.01 s). These results suggest that the novel method can accurately measure short sprint performance. (C) 2016 The Authors. Published by Elsevier Ltd.
706
711
10.1016/j.proeng.2016.06.252
Grant Details